The product performance of the top-mounted magnetic level gauge manufacturer is inseparable from whether it is installed correctly. During installation, the following points should be noted: 1. The level gauge must be installed vertically to ensure that the float assembly moves freely up and down in the main tube. 2. Magnets are not allowed to approach the main body of the liquid level gauge, otherwise it will directly affect the work of the liquid level gauge. 3. After the liquid level gauge is installed, the top-mounted magnetic liquid level gauge manufacturer needs to use magnetic steel to correct and guide the turning column once so that red is displayed below zero and white is displayed above zero. _Bullseye High Pressure Level Gauge_Top Mounted Magnetic Level Gauge

Top-mounted magnetic level gauge manufacturerGenerally, the top-mounted magnetic level gauge is divided into two parts: upper and lower structure. The upper part is the main measuring tube of the liquid level gauge. A display panel with magnetic turning plates is bound outside the tube to indicate the liquid level. This part is installed on the top of the container and connected with the flange of the container through a flange. Generally, it is optional.DN80orDN100Flange can be, flange specifications should not be lessDN80; The lower part is divided into the guide tube part, which is the channel of the float. The float in the guide tube is connected with the magnetic float in the upper measuring tube through the connecting rod. When the liquid level changes up and down, the float drives the magnetic steel to move up and down in the guide tube. The magnetic coupling of the upper float drives the flip plate in the display panel to flip to indicate the liquid level.Top-mounted magnetic level gauge manufacturerThe reed pipe level transmitter can also be bundled outside the buoy to achieve long-distance signal transmission and automatic control. _Bullseye High Pressure Level Gauge_Top Mounted Magnetic Level Gauge 

 

Top-mounted magnetic level gauge manufacturerProduct PerformanceThe quality and whether the correct installation is inseparable. During installation, the following points should be paid attention to:_bull's eye type high pressure level meter_top mounted magnetic level meter

1The installation of liquid level gauge shall beGuaranteeVertical to ensure that the floating ball assembly moves up and down freely in the main body tube. 

23. It is not allowed to have a magnetic conductor close to the main body of the liquid level gauge, otherwise it will directly affect the working of the liquid level gauge.FTrue work.

3After the installation of the level gauge,Top-mounted magnetic level gauge manufacturerIt is necessary to use magnetic steel to correct and guide the turning column once so that red is displayed below zero and white is displayed above zero.

4When the liquid level gauge is put into operation, the valve of the lower liquid introduction pipe shall be opened first to allow the liquid medium to enter the main pipe smoothly, so as to prevent the liquid medium from rising rapidly with the floating ball assembly, resulting in the failure of turning over the column and turning over randomly. If this phenomenon occurs, magnetic steel can be used to re-calibrate after the liquid level is stable.

5In order not to damage the floating ball assembly during transportation, before leaving the factoryTop-mounted magnetic level gauge manufacturerToTake the floating ball assembly out of the main tube of the liquid level gauge. After the installation of the liquid level gauge is completed, open the bottom blowdown flange, and then re-install the floating ball assembly into the main tube. Pay attention that the heavy end of the floating ball assembly is upward and cannot be inverted. IfTop-mounted magnetic level gauge manufacturerThe floating ball assembly has been installed in the main tube before leaving the factory. In order to ensure that the floating ball assembly is not damaged during transportation, we use a soft card to fix the floating ball assembly in the main tube, and only need to pull out the soft card during installation.

6,Top-mounted magnetic level gauge manufacturerAccording to the condition of the medium, the sewage flange can be opened regularly to clean the sediment of the main pipe.


Key words:

Magnetic level gauge, bull's eye type high pressure level gauge, top-mounted magnetic level gauge, side-mounted float ball level switch, no blind zone high pressure two-color water level gauge with lamp


Qidong Hengsheng Instrument Equipment Co., Ltd.

Contact: Shen Yinjing
Telephone:0086-513-83799093,83782222,83832998(switchboard)
Fax:0086-513-83780668
E-mail : hsyb@hsyb.cn 

Address: No.6, Xinghui Street, Huiping Town, Qidong City, Jiangsu Province

Business License