Anti-frost glass plate level gauge
Qidong Hengsheng Instrument Equipment Co., Ltd. is based on the purpose of people-oriented, brand establishment, and market service. It has strong technical force and complete processing and testing equipment, and has established a set of effective scientific management and operation systems. It is in similar industries. Passed the ISO9001:2008 international quality system certification.
Key words:
Key words:
Float Level Transmitter | Magnetic Level Gauge | Magnetostrictive Level Gauge
Classification:
Product Description
UHS-C anti-frost type glass plate level gauge
Overview
In liquid level measurement, low temperature (below 0 ℃) medium makes the surface of the container condensation, frost, so that the frost layer covers the surface of the container. The anti-frost type level gauge is equipped with plexiglass fins on the body, and the actual position of the medium in the container can be read through the fins, thus solving the problem that the general level gauge cannot measure the low temperature medium.
The needle valve at both ends of the instrument is equipped with a safety steel ball. When the glass plate is accidentally damaged, the steel ball can automatically close the fluid channel under the pressure of the medium in the container to play an automatic sealing role. This standard is applicable to the liquid level indicating device of low-temperature equipment in chemical and petroleum industries, with nominal pressure of 2.5, 4.0 and 6.4MPa, and operating temperature (medium temperature) of -160 ℃ ~ 0 ℃.
Selection code description
|
Product Series Name |
Description |
|
|||||||||||||||||||
|
UHS-H |
Glass plate level gauge |
|
|||||||||||||||||||
|
Code 1 |
Type of glass plate |
||||||||||||||||||||
|
|
Model |
T |
D |
C |
M |
L |
V |
||||||||||||||
|
|
Description |
Transparent type |
Reflective |
Anti-frost |
High temperature type |
No blind spot type |
High pressure type |
||||||||||||||
|
Code 2 |
Display Color |
||||||||||||||||||||
|
|
D |
Monochrome display |
|||||||||||||||||||
|
|
S |
two-color display |
|||||||||||||||||||
|
Code 3 |
Nominal pressure |
||||||||||||||||||||
|
|
□ |
Nominal pressure of level gauge (MPa) |
|||||||||||||||||||
|
Code 4 |
Form of sealing surface |
||||||||||||||||||||
|
|
Model |
FF |
RF |
M |
FM |
RJ |
T |
G |
|||||||||||||
|
|
Description |
Plane |
convex surface |
Convex |
Concave |
Ring connection surface |
Tenon surface |
Groove surface |
|||||||||||||
|
Code 5 |
Nominal diameter |
||||||||||||||||||||
|
|
DN□ |
Nominal diameter of connecting flange of level gauge |
|||||||||||||||||||
|
Code 6 |
Material of liquid contact |
Material of pressure plate |
|||||||||||||||||||
|
|
Code |
Ⅰ |
Ⅱ |
Ⅲ |
Ⅰ |
Ⅱ |
Ⅲ |
||||||||||||||
|
|
Description |
Carbon Steel |
Stainless Steel 304 |
Stainless steel 316 or 316L |
Carbon Steel |
Stainless Steel 304 |
Stainless steel 316 or 316L |
||||||||||||||
|
Code 7 |
Form |
||||||||||||||||||||
|
|
Model |
Omitted |
W |
||||||||||||||||||
|
|
Description |
Ordinary type |
With steam jacket |
||||||||||||||||||
|
Code 8 |
Mounting dimensions |
||||||||||||||||||||
|
|
□□□□□ |
Flange center distance of level gauge (mm) |
|||||||||||||||||||
|
Code 9 |
Sewage outlet |
|
|||||||||||||||||||
|
|
Model |
P |
V |
F |
|||||||||||||||||
|
|
Description |
Blowdown plug |
Blow valve |
Blowdown flange |
|||||||||||||||||
|
Code 10 |
vent |
|
|||||||||||||||||||
|
|
Model |
P |
V |
F |
|||||||||||||||||
|
|
Description |
Emptying plug |
vent valve |
Vents Flange |
|||||||||||||||||
Selection example
|
Product Series Name |
Type of level gauge |
Display Color |
Nominal pressure |
Sealing surface |
Engineering Path |
Material |
Form |
Mounting dimensions |
Sewage outlet |
vent |
|
UHS-H |
T |
S |
-5.0 |
M |
-DN50 |
III/III |
W |
-1100 |
P |
P |
|
|
Code 1 |
Code 2 |
Code 3 |
Code 4 |
Code 5 |
Code 6 |
Code 7 |
Code 8 |
Code 9 |
Code 10 |
Reed-resistance type remote transmission transmitter is a supporting instrument of UHS-A series magnetic level gauge, which is used to convert the liquid level of medium into 4 ~ 20mA standard current signal output. The sensor part of the transmitter is encapsulated in the magnetic turn-over column panel or externally bundled, with reasonable product structure and convenient installation. At the same time, the Japanese ALEPH dry reed switch is used as the sensing element, which has good product stability and long service life. It is a convenient and reliable liquid level transmitter matched with the magnetic turning column liquid level gauge. In addition, the transmitter output can be used with the light column indicator digital display adjustment alarm produced by our company to easily realize the display, control, adjustment and alarm of the liquid level.
Products are constantly improved, configuration parameters are constantly updated, and the configuration and appearance of products are subject to physical objects.
Related Products
Product inquiry
Qidong Hengsheng Instrument Equipment Co., Ltd.
Contact: Shen Yinjing
Telephone:0086-513-83799093,83782222,83832998(switchboard)
Fax:0086-513-83780668
E-mail : hsyb@hsyb.cn
Address: No.6, Xinghui Street, Huiping Town, Qidong City, Jiangsu Province